DERMAGRIP®

Ultra LT Nitrile Powder Free

D15xx-20
No Need to Compromise Comfort for Protection

Medical gloves provide protection from unwanted and dangerous substances for both healthcare professionals and patients. DERMAGRIP® Ultra LT Nitrile Examination Gloves meet and exceed international product standards to provide uncompromising protection to its users.

Dermagrip® Ultra LT Nitrile Examination Gloves are formulated with 100% nitrite (Acrylonitrile-butadiene) providing an alternative solution for individuals who are allergic to natural rubber latex. Read More

Ultra Nitrile LT Powder Free Special

Type Powder-free and non-sterile
Primary Materials Acrylonithie-butadiene
Powder No powder lubricant added
Color Blue (PMS 292U)
Design and Feature Ambidextrous, textured surface at fingers and beaded cuff
Packing 200 gloves per dispenser(X-Small to Large),180 gloves per dispenser(X-Large) 10 dispensers per carton
Product Conformance
  • Medical Device: in compliance with European Medical Device Directive 93/42/EEC (CE Class I)
  • EN 455-1:2000, EN 455-2:(2009 + A1:2015), EN 455-3 (2015) and EN 455-4 (2009)
  • Personal Protective Equipment of Complex Design Category III, in compliance with 89/686/EEC, type tested to EN 420:2003+A1:2009, EN 374-12003, EN 374-3:2003 .N 388:2003, CE 0086
  • ASTM D6319
Quality Assurance
  • US FDA Quality System Regulation (QSR)
  • 1509001 Quality Management System
  • 15013485 Quality Management System

  • Store in cool dry place
    Store in cool dry place
  • Do not expose to water
    Do not expose to water
  • Latex free
    Latex free
  • Single use only
    Single use only

Pre-shipment Quality Inspection:

Criteria Sampling Plan
Dimension N=13, AQL Median
Physical Properties N=13, AQL Median
1000ml Water Leak Test G-1, AQL 1.5
Powder Free Residue N=5
Visual Inspection for Major Defects G1, AQL 2.5
Visual Inspection for Minor Defects G1, AQL 4.0

Physical Properties

*Typical Physical Properties Before Aging After Aging
Tensile Strength (MPa) 26 21
EN 455-2 Force At Break (N) min. 6 min. 6

Dimensions

Glove Size Reorder# Palm Width (mm) Length (mm)
Extra-Small D1500-20 ≤ 80 min. 240
Small D1501-20 80 ± 10 min. 240
Medium D1502-20 95 ± 10 min. 240
Large D1503-20 110 ± 10 min. 240
Extra-large D1504-20 ≥ 110 min. 240

Thickness

Location of Thickness Measurements Single Wall (mm)
Fingers (at 15mm from the extreme tip) min. 0.07
Palm (at center of palm) min. 0.06
Cuff (at 25mm from cuff end) min. 0.05